The TM-370A+ has the same core performance, dimensions and filtration structure as the corresponding TM-370A model, with an added filter monitoring function. An optional HEPA post-filter is available for micromist, smoke and vapor applications.
Technical Specifications
| Model | TM-370A+ |
|---|---|
| Airflow at 50Hz | 1,000 m3/h |
| Motor power | 0.37 kW |
| Power supply | 3-phase 220V/380V, 50Hz/60Hz |
| Motor speed | 2,850 rpm |
| Inlet diameter | 150 mm |
| Weight | 36 kg |
| Dimensions (diameter x height) | 440 x 950 mm |
| Filter structure | Centrifugal separation, multilayer filter, optional HEPA post-filter |
| Filtration efficiency | Up to 99.97% at 0.3 micrometers with optional HEPA post-filter |
| Installation | Machine-top mounting; optional floor or wall-bracket mounting |
| Filter monitoring | Included filter monitoring function |
| Noise level | Needs Confirmation |
Specifications are based on the supplied 50Hz product table. Airflow increases at 60Hz; exact 60Hz airflow values require confirmation.
A+ Filter Monitoring Function
The A+ version adds a monitoring function to the corresponding A model. Its listed airflow, motor, inlet, weight, dimensions, filtration structure and installation options remain the same as the matching A version.
Filtration Process
- Polluted air is drawn from the machine enclosure into the lower pre-chamber.
- The rotating turbine generates centrifugal force, causing oil droplets to coalesce.
- A multilayer filter captures smaller remaining pollutant particles.
- Collected liquid returns through the drainage tube for reuse in the process where appropriate.
Maintenance
Internal filters can be accessed by opening the cover for cleaning or replacement. Maintenance intervals depend on the coolant, particulate load and operating cycle and require application confirmation.